Automatic Generator Start Module

Model Number Description
ME-AGS-N

Imagine being able to enjoy a day away all-the-while knowing your living space will stay cool and comfortable and your batteries will stay charged and ready for all of the activities that make up daily life. There’s nothing better than returning to a nice, cool, comfortable home with charged batteries after a day away. The Magnum Auto Gen Start (AGS) can make this happen.

The Magnum AGS is compatible with most major generators, including Onan, Powertech, Generac, Westerbeke, Kohler, EPS, Northern Lights, and most portable generators with electric start. Please check with your Magnum dealer for specific model compatibility.

ME-AGS-N Owner's Manual | 64-0039 Rev B

Auto Generator Start - Stand Alone

Model Number Description
ME-AGS-S

The ME-AGS-S Auto Generator Start Controller (AGS Controller - Standalone Version) - The ME-AGS-S is the 'standalone' version of Magnum Energy's Automatic Generator Start (AGS) controllers. This auto generator start controller can automatically start your generator based on battery voltage or high temperature. Adjustable settings include: run time, start volts DC, start temp, quiet time, and 24 hour clock. Works with ME Series, MM Series, MMS Series, MS Series, MS-PAE Series and RD Series. ME-AGS-S kit includes: AGS module, Remote on/off/test switch, switch bezel, a 25' 6-wire cable, and has basic adjustments starting on battery voltage or temperature. *The ME-AGS-S does not require an inverter / charger. Imagine being able to enjoy a day away all-the-while knowing your living space will stay cool and comfortable and your batteries will stay charged and ready for all of the activities that make up daily life. There's nothing better than returning to a nice, cool, comfortable home with charged batteries after a day away. The Magnum Auto Gen Start (AGS) can make this happen.The Magnum AGS is compatible with most major generators, including Onan, Powertech, Generac, Westerbeke, Kohler, EPS, Northern Lights, and most portable generators with electric start. Please check with your Magnum dealer for specific model compatibility.

Owner's Manual: ME-AGS-S Auto Gen Start Stand Alone Owner's Manual | 64-0004 Rev C

 

Battery Monitor Kit

Model Number Description
ME-BMK

The ME-BMK/ME-BMK-NS is a single battery bank amp-hour meter that monitors and provides important information about the condition of the battery. This information will let you know how much energy you have available, and let you plan your electrical usage to ensure the battery is not being over-discharged.

The ME-BMK is easy to install and is designed to be networked with a Magnum Energy inverter/charger using a remote (ME-RC50 or ME-ARC50) or router (ME-RTR) to display  information about your battery bank.

Data Sheet: BMK_batterymonitorkit_data_sheet_revc.pdf

Owner's Manual: ME-BMK / ME-BMK-NS Battery Monitor Kit Owner's Manual | 64-0013 Rev B

Conduit Box

Model Number Description
ME-CB

The ME-CB Conduit Box fits on the front side of the Magnum ME, MS, MS-PAE and RD Series inverters. This conduit box accommodates installations where the electrical code requires the AC and/or DC wiring to be enclosed and protected by conduit.

This enclosure provides knockouts for use with 1/2”, 3/4”, 1” and 2” trade size conduit and adds just over 5” (13 cm) to the length of the inverter.

ME-CB Conduit Box Installation Guide | 64-0018 Rev B

MagWeb Monitoring Kit

Model Number Description
ME-MW-W (Wireless) or ME-MW-E (ethernet)

The MagWeb is a powerful and cost effective tool for remotely monitoring Magnum Energy’s inverters and accessories. Installed on the Magnum network, the MagWeb provides live Internet monitoring of the inverter, battery monitor, and automatic generator start module. Using your always on Internet connection, the MagWeb makes live and historical conditions available to you through a web browser at data.magnumenergy.com.

Data Samples

The MagWeb constantly streams data to your personal web pages, providing details on Current Conditions, Current Settings, and Daily Summaries for historical records. Monitoring includes:

  • Inverter/Charger:
    • Status
    • Program settings
    • Faults
    • DC volts, DC amps
    • Invert, charge LEDs
    • Tech menus
  • Battery Monitor status
  • Auto Gen Start (AGS) status

     ME-MW-W Owner's Manual     64-0050-Rev-A-MagWeb.pdf
     ME-MW-E Owner's Manual     64-0055-Rev-A-MagWeb-E.pdf
     ME-MGT-MW Owner's Manual     64-0086 A Owner Manual, ME-MGT-MW_Web.pdf
     MagWeb Data Sheet     MagWeb_datasheet_revB_#64-0650_web.pdf

Smart Battery Combiner

Model Number Description
ME-SBC

The Magnum Smart Battery Combiner (ME-SBC) is designed to monitor and charge a second battery using a portion of the current that is charging a main battery.

The ME-SBC uses MOSFETs, which is a bidirectional electronic switch, control circuit that eliminates a significant voltage drop and provides automatic turn on and off based on adjustable voltage setpoints; allowing different batteries to be charged from a single charging source and preventing over or under charging. 

64-0019-ME-SBC-web.pdf
SBC_smartbatterycombiner_data_sheet_revb.pdf

Outdoor Enclosure

Model Number Description
MP-ODE

The NEMA-rated outdoor enclosure (MP-ODE) is a weather-resistant, protective outdoor enclosure designed to house a Magnum MMP panel, a Magnum inverter/charger, a PT-100 charge controller, and a remote control. The aluminum, white powder-coated enclosure has gasket-lined openings to protect against falling rain, sleet, snow, and external ice formation. Ventilation slots are screened to prevent debris or pests while ensuring adequate airflow. And multiple knockouts allow easy conduit installation.

Filter Box

Model Number Description
MS-CEFB

The MS-CEFB is an EMI (electromagnetic interference) filter designed to control conducted emissions on the AC and DC side of Magnum Energy’s MS-E and MS-PE Series inverters. It is used to ensure that stringent international standards for electromagnetic compatibility (EMC) are met.